Four Channel Gas Monitor

Four Channel Gas Monitor
  • Four Channel Gas Monitor
Ask For Price
Product Price :Get Latest Price

Product Details:

ModelGT-4425-WP
ApplicationIndustrial
MaterialABS+PC
Warranty1 Year
Accuracy1% of the full scale value
TheoryTemperature Recorder

Feature:

  • Reducing cable from Transmitter to Gas Monitor.
  • Display of Gas Concentration along with its Unit & 'Gas Name' for Four no channels.
  • Highly informative user friendly LCD display & keyboard interface with separate indication for Gas Concentration as well as Alann conditions along with LED indications.
  • Micro-controller Based Latest, Accurate, Reliable & High Performance Technology that Eliminates False Alarm.
  • Accepts of 4 no RS-485 MODBUS RTU PROTOCOL from Toxic/Combustible/02 Transmitter
  • Audio as well as Visual Alarm Indication
  • One in no, Independent isolated Alarm Relay Output can be independently configured as per the requirement For Each Channel.
  • One no. Independent Isolated Alarm Relay Output for Fai !safe operation.
  • Optional programmable isolated Voltage or Current Output with Configurable Range for any 2 no channel out of4 no.
  • Optional Isolated RS 485 Communication Port with Modbus RTU Protocol for PLC/DCS/Annuniciator
  • Relay/ Buzzer acknowledgment facility from Front panel as well as From Rear terminal
  • SeIftesting ofAlarm LEDs, Relays, Voltage or Current Output.
  • Test Mode' provided to check the electronics without Gas Transmitter Connection.
  • Password protected programming menu with password changing.

Applications:
  • Refineries
  • Paint Shop
  • Sewage Plants
  • Hotel Industries
  • Fertilizers Plants
  • Stack Monitoring
  • Gas Cylinder Bank
  • Pulp & Paper Plants
  • Gas Pipeline Projects
  • Heat Treatment Plants
  • Automotive Industries
  • Oil and Gas industries
  • Gas Metering Stations
  • Chemical Storage Area
  • Burner / Furnace Areas
  • Power & Industrial Plants
  • Bullet Yard / Storage Yards
  • Chemical Processing Plant
  • Coal Mine and Confined Areas
  • Chemical & Petrochemical Plants
  • Acid Alkalizes & Dyes Mfg. Plants
  • Offshore Drilling & Processing Platforms
Request
Callback
Yes! I am interested
View PDF

Four Channel Gas Monitor

Four Channel Gas Monitor
  • Four Channel Gas Monitor
Ask For Price
Product Price :Get Latest Price

Product Details:

BrandAmbetronics
ApplicationIndustrial
MaterialABS+PC
Warranty1 Year
Accuracy1% of the full scale value
TheoryTemperature Recorder

Feature:

  • Reducing cable from Transmitter to Gas Monitor.
  • Display of Gas Concentration along with its Unit & 'Gas Name' for Four no channels.
  • Highly informative user friendly LCD display & keyboard interface with separate indication for Gas Concentration as well as Alann conditions along with LED indications.
  • Micro-controller Based Latest, Accurate, Reliable & High Performance Technology that Eliminates False Alarm.
  • Accepts of 4 no RS-485 MODBUS RTU PROTOCOL from Toxic/Combustible/02 Transmitter
  • Audio as well as Visual Alarm Indication
  • One in no, Independent isolated Alarm Relay Output can be independently configured as per the requirement For Each Channel.
  • One no. Independent Isolated Alarm Relay Output for Fai !safe operation.
  • Optional programmable isolated Voltage or Current Output with Configurable Range for any 2 no channel out of4 no.
  • Optional Isolated RS 485 Communication Port with Modbus RTU Protocol for PLC/DCS/Annuniciator
  • Relay/ Buzzer acknowledgment facility from Front panel as well as From Rear terminal
  • SeIftesting ofAlarm LEDs, Relays, Voltage or Current Output.
  • Test Mode' provided to check the electronics without Gas Transmitter Connection.
  • Password protected programming menu with password changing.

Applications:
  • Refineries
  • Paint Shop
  • Sewage Plants
  • Hotel Industries
  • Fertilizers Plants
  • Stack Monitoring
  • Gas Cylinder Bank
  • Pulp & Paper Plants
  • Gas Pipeline Projects
  • Heat Treatment Plants
  • Automotive Industries
  • Oil and Gas industries
  • Gas Metering Stations
  • Chemical Storage Area
  • Burner / Furnace Areas
  • Power & Industrial Plants
  • Bullet Yard / Storage Yards
  • Chemical Processing Plant
  • Coal Mine and Confined Areas
  • Chemical & Petrochemical Plants
  • Acid Alkalizes & Dyes Mfg. Plants
  • Offshore Drilling & Processing Platforms
Request
Callback
Yes! I am interested
View PDF

Channel Intelligent Gas Monitoring System

Channel Intelligent Gas Monitoring System
  • Channel Intelligent Gas Monitoring System
Ask For Price
Product Price :Get Latest Price

Product Details:

Display TypeDigital
Power SourceBattery
Supply Voltage190 to 270 V AC
Power Rating 20 W
Transmitter 24 V DC, 4 A
Storage Temp-20 to 60 deg celsius
Operating Temp-30 to 70%
Cabinet MaterialPolycarbonatc
Cable Entry Thermoplastic (TP-68)

Channel Intelligent Gas Monitoring System

Feature:

  • IntelliMaster is a 16/32 Channel Modbus ID Monitoring System for Transmitters are having RS-485 Modbus RTU Network Connectivity.
  • IntelliMaster has one more RS - 485 Modbus RTU Port for Remote Repeater Panel called as IntelliRepeaterwhich will repeat all readings &Alarm conditions.
  • Multidrop RS -485 Port eliminates separate cabling to each Transmitter and Monitor Panel.
  • Modbus - RTU Network can be connected in Ring Topology for Redendency.
  • Scan time for 16 Transmitter <5 sec. & for 32 Transmitter < 10 sec.
  • Large 16 x4 line Display with Configurable Backlit Option.
  • Auto Page Changing Facility available for easy viewing of Data, Relay & Fault Condition of each Transmitter.
  • Optional 8 Relays (SPDT) rated "10A/ 250VAC, 10A/ 30VDC" as Warning / Trip Relay with 1 no. Failsafe Relay which activates for UNDER / OVER / OPEN Condition of Transmitter.
  • Separate Alarm Setting for each Transmitterwith Logic High / Low & Latching Facility.
  • Password Protected Menu with Password Changing Facility.
  • Easy Handling & Programming with 3 keys on Front Panel.

Applications:
  • Clean Room Monitoring & Validation in Pharmaceutical, Laboratories, Bioscience
  • Room Mapping in Pharmaceutical
  • Pharmaceutical process validation with graph & scale report in Autoclave
  • Healthcare, Hospitals, Shopping Malls
  • Breweries, Steel Plants, Gas Turbines,
  • Leak detection, Solvent Vapors,
  • Personal Monitoring, Compressor Stations,
  • Emergency response, Equipment Maintenance
  • Pulp & Paper Industry, Fuel Loading Facilities
  • Waste Water Treatment Plants,
  • LNG I LPG Processing & Storage Facilities
  • Refineries & Petrochemical Plants Including Offshore
  • Drilling & Plant Shut-downs
  • ISO Certification Records, Validation process certifying,
  • Chemical & Hazardous area where data monitoring is essential
  • Food Processing
  • Cold Storage & Chilling Plant
  • Building Management & Energy Saving Systems
  • Meteorological, Weather Forecast Applications
  • Remote Indication location on tank taps as used in liquid level sensing & control

Other details:
  • Input :16132 Transmitters having RS-485 Modbus RTU Port.
  • Display: 16 x 4 Alphanumeric LCD with Configurable Backlit option. 8 LEDs to indicate status of IntelliMaster. 48 LEDs to indicate Alarm status of Transmitters in Group Function.
  • Control Action : i) 2 independent Alarm set points for each Transmitter with Latch & Non-Latch Facility. ii) User selectable Hysteresis & Logic Operation.
  • Setting : By using 3 keys on the front panel for WP & FLP models.

Performance
  • Scan Time: Less than 5 Sec. for 16 Transmitters having RS-485 Modbus RTU Port. Less than 10 Sec. for 32 Transmitters having RS-485 Modbus RTU Port.
Request
Callback
Yes! I am interested
View PDF

Channel Intelligent Gas Monitoring System

Channel Intelligent Gas Monitoring System
  • Channel Intelligent Gas Monitoring System
Ask For Price
Product Price :Get Latest Price

Product Details:

Display TypeDigital
Power SourceBattery
Supply Voltage 190 to 270 V AC
Power Rating 20 W
Transmitter 24 V DC, 4 A
Cable 1.5 mm
Storage Temp-20 to 60 deg celsius
Operating Temp-30 to 70%
Humidity Below 95%
Protection ClassW-65

Channel Intelligent Gas Monitoring System

Feature:

  • IntelliMaster is a 16/32 Channel Modbus ID Monitoring System for Transmitters are having RS-485 Modbus RTU Network Connectivity.
  • IntelliMaster has one more RS - 485 Modbus RTU Port for Remote Repeater Panel called as IntelliRepeater which will repeat all readings &Alarm conditions.
  • Multi drop RS -485 Port eliminates separate cabling to each Transmitter and Monitor Panel.
  • Modbus - RTU Network can be connected in Ring Topology for Redundancy.
  • Scan time for 16 Transmitter <5 sec. & for 32 Transmitter < 10 sec.
  • Large 16 x4 line Display with Configurable Backlit Option.
  • Auto Page Changing Facility available for easy viewing of Data, Relay & Fault Condition of each Transmitter.
  • Optional 8 Relays (SPDT) rated "10A/ 250VAC, 10A/ 30VDC" as Warning / Trip Relay with 1 no. Failsafe Relay which activates for UNDER / OVER / OPEN Condition of Transmitter.
  • Separate Alarm Setting for each Transmitter with Logic High / Low & Latching Facility.
  • Password Protected Menu with Password Changing Facility.
  • Easy Handling & Programming with 3 keys on Front Panel.

Applications:
  • Clean Room Monitoring & Validation in Pharmaceutical, Laboratories, Bioscience
  • Room Mapping in Pharmaceutical
  • Pharmaceutical process validation with graph & scale report in Autoclave
  • Healthcare, Hospitals, Shopping Malls
  • Breweries, Steel Plants, Gas Turbines,
  • Leak detection, Solvent Vapors,
  • Personal Monitoring, Compressor Stations,
  • Emergency response, Equipment Maintenance
  • Pulp & Paper Industry, Fuel Loading Facilities
  • Waste Water Treatment Plants,
  • LNG I LPG Processing & Storage Facilities
  • Refineries & Petrochemical Plants Including Offshore
  • Drilling & Plant Shutdowns
  • ISO Certification Records, Validation process certifying,
  • Chemical & Hazardous area where data monitoring is essential
  • Food Processing
  • Cold Storage & Chilling Plant
  • Building Management & Energy Saving Systems
  • Meteorological, Weather Forecast Applications
  • Remote Indication location on tank tops as used in liquid level sensing & control

Other details:
  • Input:16132 Transmitters having RS-485 Modbus RTU Port.
  • Display: 16 x 4 Alphanumeric LCD with a Configurable Backlit option. 8 LEDs to indicate the status of IntelliMaster. 48 LEDs to indicate Alarm status of Transmitters in Group Function.
  • Control Action: i) 2 independent Alarm set points for each Transmitter with Latch & Non-Latch Facility. ii) User selectable Hysteresis & Logic Operation.
  • Setting: By using 3 keys on the front panel for WP & FLP models.

Performance
  • Scan Time: Less than 5 Sec. for 16 Transmitters having RS-485 Modbus RTU Port. Less than 10 Sec. for 32 Transmitters having RS-485 Modbus RTU Port.
Request
Callback
Yes! I am interested
View PDF

Dual Channel Gas Monitor

Dual Channel Gas Monitor
  • Dual Channel Gas Monitor
Ask For Price
Product Price :Get Latest Price

Product Details:

BrandAmbetronics
ApplicationIndustrial
MaterialABS+PC
Protection ClassIP - 40
Dimension96 mm (H) x 96 mm (W) x 170 mm (D)
Cutout92 mm (H) x 92 mm (W)
Accuracy1% of the full scale value

Feature:

  • Display of Gas Concentration along with its Unit & `Gas Name'.
  • Highly informative user friendly LCD display & keyboard interface with separate indication for Gas Concentration as well as Alarm conditions along with LED indications.
  • Micro-controller Based Latest Accurate, Reliable & High Performance Technology that Eliminates False Alarm.
  • Accepts of 4-20mAAnalog Input OR RS-485 Modbus RTU Protocol as a Input from Toxic / Combustible / 02 Transmitter.
  • Audio as well as VisualAlarm Indication Two/Four Independent isolated Alarm Relay Output can be programmable.
  • One no. isolated Alarm Relay Output for Failsafe operation.
  • Optional isolated Current or Voltage Output with programmable Range .
  • Optional Isolated RS -485 Communication Port with Modbus RTU Protocol.
  • Relay/Buzzer acknowledgment facility from Front panel as well as From Rear terminal Self testing ofAlarm LEDs, Relays, Voltage or Current Output.
  • 'Test Mode' provided to check the electronics without Gas Transmitter Connection .
  • Password protected programming menu with password changing.

Applications:

  • Refineries
  • Paint Shop
  • Sewage Plants
  • Hotel Industries
  • Fertilizers Plants
  • Stack Monitoring Gas Cylinder Bank
  • Pulp & Paper Plants
  • Gas Pipeline Projects
  • Heat Treatment Plants
  • Automotive Industries
  • Oil and Gas industries
  • Gas Metering Stations
  • Chemical Storage Area
  • Burner / Furnace Areas
  • Power & Industrial Plants
  • Bullet Yard / Storage Yards

Model Overview:

  • Input : Accepts 4 to 20mA analog OR RS-485 Modbus RTU Protocol Output from Oxygen /Toxic / Combustible Gas Transmitter.
  • Range : 0 to 9999 in unit PPM or % LEL or %VN Programmable by user.
  • Display : 16x2 Alphanumeric LCD Display with auto Backlit option. 8 LEDs to indicate status of instrument
  • Control Action : i) Two independent Alarm Set Points with Latch & Non-Latch facility for each Channel independently. h) User selectable Hysteresis & Logic option. iii) Failsafe Relay for fault condition.
  • Setting : By 3 Keys on front panel

Chemical Processing Plant
  • Coal Mine and Confined Arcas
  • Chemical & Petrochemical Plants
  • Acid Alkalizes & Dyes Mfg. Plants
  • Offshore Drilling & Processing Platforms
  • performance:
  • Measurement Accuracy : t 1% of full-scale.
  • Response Time : <1 Sec typically
  • Start-up Time : Less than 30 Seconds.

Electrical:

  • Power Supply: 90 to 300 VAC / DC.
  • Power Consumption: Less than 10 Watt.
  • Connection: 1.5 mm' Flexible or Armoured Shielded Cable.

Output Signal :
  • Standard : It has five No. isolated relays ;One for Failsafe of 2A/120VAC , 2A/74VDC rating & Two no. Alarm relay of 10A/ 250VAC , 10A/30VDC rating for each channel can be configured as per the requirment.
  • Optional : Isolated 0-20mA / 4-20mA / 0-5VDC / 0-10VDC Output with configurable Range for each channel.
  • Optional : Isolated RS • 485 Communication Port with Modbus RTU Protocol.

Panel Mounting Housing
  • Protection Class : IP - 40
  • Cabinet Material : ABS Enclosure
  • Termination Dimension : 1.5mm2 Connector
  • Dimension: 96 mm (H) x 96 mm (W) x 170 mm (D)
  • Cutout : 92 mm (H) x 92 mm (W)
  • Mounting : Panel
  • Weight : Approx I Kg.
Request
Callback


Additional Information:

  • Item Code: GM-2215-wp
Yes! I am interested
View PDF

Dual Channel Gas Monitor flameproof

Dual Channel Gas Monitor flameproof
  • Dual Channel Gas Monitor flameproof
Ask For Price
Product Price :Get Latest Price

Product Details:

Model NoGM-2215-FLP
Gas TypeNatural Gas, Combustible Gas
Display TypeDigital
Power SourceBattery
BrandAmbetronics
Detector FeaturesAdjustable Sensitivity

We are the leading and prominent Manufacturer, Trader and Exporter of Dual Channel Gas Monitor.
Request
Callback


Additional Information:

  • Item Code: GM-2215_FLP
Yes! I am interested

Four Channel Gas Monitor

Four Channel Gas Monitor
  • Four Channel Gas Monitor
Ask For Price
Product Price :Get Latest Price

Product Details:

Gas TypeNatural Gas, Combustible Gas
BrandAmbetronics
Display TypeDigital
Power SourceBattery
Detector FeaturesAdjustable Sensitivity
ApplicationIndustrial

We are the leading and prominent Manufacturer, Trader and Exporter of Four Channel Gas Monitor.
Request
Callback


Additional Information:

  • Item Code: GM-4425-WP
Yes! I am interested

Intelli Master Intelligent Monitoring System

Intelli Master Intelligent Monitoring System
  • Intelli Master Intelligent Monitoring System
Ask For Price
Product Price :Get Latest Price

Product Details:

BrandAmbetronics
MaterialABS Plastic
TypeIntelligent Controller
Case Size 48 x 48 mm
InputThermocouple
Analog OutputYes
AlarmYes
Setback FunctionYes

We are the leading and prominent Manufacturer, Exporter and Trader of Intelli Master Intelligent Monitoring System.
Request
Callback
Yes! I am interested

NDIR Gas Transmitter GT-2511-FLP-IR

NDIR Gas Transmitter GT-2511-FLP-IR
  • NDIR Gas Transmitter GT-2511-FLP-IR
Ask For Price
Product Price :Get Latest Price

Product Details:

Output Value4 - 20 mA
BrandAmbetronics
Power Supply18 to 36 V DC
DisplayDigital
IndicationLCD
Warranty1 Year
Display TypeDigital

We are the leading supplier of Smart Gas Transmitter GT-2511-FLP-IR. The clients can avail the products at best market price.

Features:

  • The quickest route into the infrared market.
  • IR gas detector capable of detecting the smallest leak of gases.
  • Highly resistant to poisoning and etching.
  • Explosion proof housing for explosive environment.
  • Digital display of Gas Concentration on the LCD with Auto backlit.
  • Easy handling & programming with 4 keys.
  • Password protected function menu.
  • Operational Power Supply From 18 to 36 Vdc With Polarity Protection.
  • Standard 4-20 mA output with fault indication current output.
  • Low, High configurable Alarms with Visual alerts.
  • Optional alarm relay contact closure.
  • One man auto software calibration.
  • Gas concentration can be displayed in %V/V, % LEL or PPM.

Applications:

  • Breweries
  • Steel Plants
  • Gas Turbines
  • Leak detection
  • Solvent Vapors
  • Personal Monitoring
  • Compressor Stations
  • Emergency response
  • Pulp & Paper Industry
  • Fuel Loading Facilities
  • Equipment maintenance
  • Incoming cylinder inspection
  • Waste water treatment plants
  • LNG / LPG Processing & Storage facilities
  • Refineries & Petrochemical plants including offshore drilling & plant shut-downs.
Request
Callback


Additional Information:

  • Item Code: GT-2511-FLP-IR
Yes! I am interested
View PDF

Four Channel Gas Monitor

Four Channel Gas Monitor
  • Four Channel Gas Monitor
Ask For Price
Product Price :Get Latest Price

Product Details:

BrandAmbetronics
ApplicationIndustrial
MaterialABS+PC
Accuracy1% of the full scale value
TheoryTemperature Recorder

Features:

  • Reducing cable from Transmitter to Gas Monitor.
  • Display of Gas Concentration along with its Unit & `GasNamet for Four no channels.
  • Highly informative user friendly LCD display & keyboard interface with separate indication for Gas Concentration as well a sA larm conditions along with LED indications.
  • Micro-controller Based Latest, Accurate, Reliable & High Performance Technology that Eliminates False Mann.
  • Accepts of 4 no RS-485 MODBUS RTU PROTOCOL from Toxic/ Combustible/ 02 Transmitter
  • Audio as well as Visual Mann Indication One in no, Independent isolated Alarm Relay Output can be independently configured as per the requirement For Each Channel.
  • One no. Independent Isolated Alarm Relay Output for Fail safe operation.
  • Optional programmable isolated Voltage or Current Output with Configurable Range for any 2 no channel out of 4 no.
  • Optional Isolated RS - 485 Communication Port with Modbus RTU Protocol for PLC/DCS/Annunciator
  • Relay / Buzzer acknowledgment facility from Front panel as well asFrom Rear terminal
  • Self testing of Alan LEDs, Relays, Voltage or Current Output.
  • 'Test Mode 'provided to check the electronics without Gas Transmitter Connection.
  • Password protected programming menu with password changing.

Applications:

  • Refineries
  • Paint Shop
  • Sewage Plants
  • Hotel Industries
  • Fertilizers Plants
  • Stack Monitoring
  • Gas Cylinder Bank
  • Pulp & Paper Plants
  • Gas Pipeline Projects
  • Heat Treatment Plants
  • Automotive Industries
  • Oil and Gas industries
  • Gas Metering Stations
  • Chemical Storage Area
  • Burner / Furnace Areas
  • Power & Industrial Plants
  • Bullet Yard / Storage Yards
  • Chemical Processing Plant
  • Coal Mine and Confined Areas
  • Chemical & Petrochemical Plants
  • Acid Alkalizes & Dyes Mfg. Plants
  • Offshore Drilling & Processing Platforms
Request
Callback


Additional Information:

  • Item Code: GM-4425-FLP
Yes! I am interested
View PDF

Flameproof Loop Powered Gas Transmitter

Flameproof Loop Powered Gas Transmitter
  • Flameproof Loop Powered Gas Transmitter
Ask For Price
Product Price :Get Latest Price

Product Details:

Accuracy1% of the full scale value
ApplicationIndustrial
Warranty1 Year
BrandAmbetronics

Feature:

  • Industrial Standard, 4.20 mA 0/P With Respect To Gas Concentration
  • Loop Test, Assures Proper Operation Of The Transmitter Without
  • Calibration Gas
  • Power On Startup Through Intelligent Electronic, Self Driven Menu
  • Microcontroller Based Software Calibration - No Trim Pots
  • Calibration Possible In Atmospheric Air
  • Easy Programming With Password Protection
  • Easy-to-read Display, Fast Response
  • Easy To Replace Sensor At The Field-plug-in Module
  • Built-in Reverse Polarity Protection r No Additional Power Required
  • Highly Reliable, Fast, Accurate For Specific Gas Detection
  • Excellent Long Term Stability £ User Friendly, Simple To Operate & Easy To Install
  • Reduced Operating, Maintenance And Installation Cost,
  • One Man Calibration r Suitable In Hazardous Area ATEX, CCOE,
  • CMRI & IP-65 Approved r Ready To Use With Any DCS, PLC & AMBETRONICS Controllers
  • Digital Filter to smooth input signal

Applications:

  • Pulp & Paper Plants
  • Chemical & Petrochemical Plants
  • Acid Alkalizes & Dyes Mfg. Plants
  • Chemical Processing Plant Offshore Drilling & Processing Platforms
  • Refineries
  • Stack Monitoring
  • Chemical Storage Area
  • Ambient Monitoring
  • Sewage Plants
  • Fertilizers Plants
  • Power & Industrial Plants Gas Metering Station
  • Bullet Yard / Storage Yard
  • Oil and Gas industries
  • Coal Mine and Confined Area
  • Gas Pipeline Project
Request
Callback


Additional Information:

  • Item Code: GT-1000_FLP_flameproof
Yes! I am interested
View PDF

VOC Detector

VOC Detector
  • VOC Detector
  • VOC Detector
Ask For Price
Product Price :Get Latest Price

Product Details:

ModelGT-2511-PID

Features:
  • Higher accuracy and better lifetime achieved using Photo Ionization Detection(PID) sensor Technology.
  • Optimized for detection of smallest leak of VOCs (IP <10.6eV).
  • Highly resistant to poisoning and etching.
  • Capable of detecting down to PPB, PPM.
  • Auto ranging of Gas concentration from PPB to PPM.
  • Digital Alphanumeric display with Auto backlit.
  • Standard 4-20mA signal output with configurable range.
  • Easy handling and programming with 3 keys.
  • Can be programmed using Remote Control from 10 meters line of site distance.
  • Non - Intrusive programming for Flameproof model using Magnetic pen.
  • Password protected programming menu.
  • One man Auto software Gas calibration.
  • Optional Alarm relay contacts with two configurable Alarm levels.
  • Optional STEL and TWA set points can be configured for all VOCs.
  • Optional RS-485 communication port with MODBUS RTU Protocol.

Applications:

  • Offshore
  • Chemical
  • Processing
  • Pulp & Paper
  • Manufacturing
  • Pharmaceutical
  • Indoor air Quality
  • Solvent Recovery system
  • Industrial painting & coating
  • Waste water treatment plants
  • Refineries & Petrochemical plants including offshore drilling & plant shut-downs
Request
Callback


Additional Information:

  • Item Code: GT-2511_PID
  • Delivery Time: 3 to 4 weeks
Yes! I am interested
View PDF

Signal Conditioning Unit For Hydrogen Gas

Signal Conditioning Unit For Hydrogen Gas
  • Signal Conditioning Unit For Hydrogen Gas
Ask For Price
Product Price :Get Latest Price
Approval & Compliance:
CE Mark :
Conforms with essential requirement of :
• Electromagnetic Compatibility Directive 2004/108/EC
• Compliance to EN50270:2006
• Low voltage Directive 2006/95/EC
Compliance with the IEC 60945 Standard for Marine application
Technical Specifications:

  • SCU Information
  • Type : Microcontroller
  • Model Number : RK-220
  • Make : M/S Ambetronics Engineers Private Limited
  • Mounting : 19 Inch Rack
  • Housing : Aluminium, 3U Height (19 Inch) Rack
  • Input Signal : 4-20 mA from Sensor (GT-2511-FLP)
  • Display Range : 0 to 800 PPM ( 0 to 2 % LEL) For Hydrogen Gas
  • Resolution : 1 PPM
  • Accuracy : ± 5% of Full Scale Range (Sensor, Signal conditioning unit & Display Unit all Combined)
  • Response time : 5-10 Seconds with 800 PPM ( 0 TO 2% LEL) Hydrogen Gas (Sensor, Signal conditioning unit &
  • Display Unit all Combined)

Specifications:

  • Indications : 3 Digit 7 segment LED display & 20 segment Red colour Bargraph Analog display
  • LED Indications : AL1 LED for Warning Alarm, AL2 LED for Emergency Alarm, HTY (Healthy / Fault ) LED, Calibration ( CAL) LED , Program ( PRG) LED
  • Alarm Setting Range : Set points can be set in between 0 to 800 PPM ( 0 to 2% LEL) for H2 Gas for AL1 (Warning Alarm) & AL2 (Emergency Alarm)
  • Alarm setting for Relay Operation : Setting Programmable, Latch / Non-Latch
  • Acknowledge Facility for Latched : ESC/ACK Key from Front Side & Remote ACK from Rear Side Relay
  • Programming Settings in SCU : By Using the front 4 no Keys, Set/Next, Up, Down, ESC / ACK Calibration (Zero & (Adjustments ) Span) setting, Settings for Warning & Emergency alarms, Fault Relay can be done by using above keys.
  • Distance Between SCU & Sensor : Approx. 300 Meters (700 Meters For 4 No. Sensors)
Electrical
  • Power supply requirement : 24 VDC from SMPS
  • Power consumption : 3.6 Watt max at 24VDC
  • SMPS Supply : 230VAC +/- 10%, 50Hz Operated & having 24VDC Output to Power the SCUs & also provides 24VDC Supply to the sensor
SCU Output:
  • Digital Output for Warning & Emergency : 2 Numbers Relays, Changeover potential free Contact Output for Warning & Emergency Alarms (One For Each) First Relay with 1 Change over contact (NO-C-NC) for the AL1 (Warning Alarm) Second Relay with 1 Change over contact (NO-C-NC) for the AL2
  • (Emergency Alarm)
  • Digital Output for Fault of Sensor & SCU : Fault Relay with 1 Number Change over Potential free Relay Contacts (NO-C-NC)
  • Contact rating of the Relays, : 24VDC 1A, L/R upto 15 ms (Inductive)


SCU Error Indication & Self Diagnostics

  • Sensor connection to SCU Break / Open : SCU LED display will show the 'oPn' AL1 & AL2 Alarm Relay contacts will change Over to
  • Normally ON & also AL1 & AL2 LED Indication will be OFF Fault Relay will change Over to
  • Normally OFF
  • Hydrogen Detection Sensor connection : SCU LED display will show the 'oPn' AL1 & AL2 Alarm Relay contacts will change Over to
  • Break / Open Normally ON & also AL1 & AL2 LED Indication will be OFF Fault Relay will change Over to
  • Normally OFF
  • Detected H2 gas is maximum than Sensor : SCU LED display will show the 'our' Detection Range AL1 & AL2 Alarm Relay contacts
  • Detection Range will change Over to Normally OFF & also AL1 & AL2 LED Indication will become ON Fault
  • Relay will remain Normally ON.
  • Self-Test mode : When DOWN key pressed for the 5 sec, All LED's & All segments of the Bargraph, All LED
  • Displays Segments will glow & All Relay will get Activated to Show the SCU is working is Ok.