Product Details:
Parameter to be Monitored | Temperature |
Type of Data Logger | Mechanical Data Logger |
Usage | Industrial |
Installation depth | min. 102 mm |
Software | Free DAQ Manager software for multi channel controller can be downloaded directly from section Down |
Panel cutout dimensions | 137 x 137 mm |
Case dimensions | 144 x 144 x 100 mm |
Case material | NORYL - GFN2S E1 |
Internal memory capacity | 1,5 GB |
Power supply | 19V / 50V DC; 16V / 35V AC or 85 / 260V AC/DC | ||||||
Input | up to 15 universal inputs; 72 analogue inputs (0/4-20 mA or 0/1-5V or 0/2-10V) max.; 72 digital inputs max.; 36 thermocouple inputs max.; 18 RTD inputs max.; 12 counter/ flow meter/ ratemeter inputs max.; 1 digital input 24V DC (available in standard, integrated with PS3 or PS4 power supply module) | ||||||
Power consumption | typical 25 VA; max. 35 VA | ||||||
Display | 5.7 inch graphic TFT, 16-bit colour, 320 x 240 pixels, with touchscreen | ||||||
Measurement range | depends on input | ||||||
Communication interface | standard: RS-485 (Modbus RTU), 1 x USB Host; ETU version: 1 or 2 x USB Host, 1 x Ethernet 10 MB; enhanced ACM version: 2 x RS-485, 1 x RS-485/232, 1 or 2 x USB Host, 1 x Ethernet 10 MB | ||||||
Output | 24 analog (4-20 mA) or 36 relay (1A/250V) / 72 SSR outputs or 18 relay 5A/250V max., sensor supply: 24 V DC +- 5% (200 mA max. for current inputs) | ||||||
Storage temperature | -10 DegreeC / 70 DegreeC or -20 DegreeC / 70 DegreeC (depending on version) | ||||||
Available data recording speed | from 0,1 s to 24 h with resolution 0,1 s | ||||||
Internal memory capacity | 1,5 GB | ||||||
Case | panel mounting | ||||||
Operating temperature | 0 DegreeC / 50 DegreeC (standard), -20 DegreeC / 50 DegreeC (option) | ||||||
Protection class |
| ||||||
Additional Information:
Product Details:
Parameter to be Monitored | Temperature, Pressure |
Type of Data Logger | Digital Data Logger |
Model | TC_800-WP |
No. of Channels | Single Channel |
Enclosure | Weatherproof |
Usage | Industrial |
Warranty | 1 Year |
Display | LED |
Accuracy | 1% of the full scale value |
Additional Information:
Product Details:
Minimum Order Quantity | 1 onward |
Parameter to be Monitored | Pressure, Temperature, Humidity |
Model Name/Number | UIP-1600-D |
Type of Data Logger | Wireless Data Logger, Digital Data Logger |
Usage/Application | Vaccine Freezer |
Display | LED |
Dimension | 96mm (H) x 192 mm (W) x 225 mm (D) (with connector) |
Brand | Ambetronics |
Model | UIP-1600D-PMH |
Usage | Industrial, Laboratory, PHARMA,CALIBRATION |
No. of Channels | Multichannel |
Warranty | 1 Year |
Accuracy | 1% of the full scale value |
Enclosure | ABS Plastic |
No of Channels | Multichannel |
Additional Information:
Product Details:
Minimum Order Quantity | 10 Number |
Parameter to be Monitored | Humidity, Parameter, Temperature, Pressure |
Type of Data Logger | 8 CHANNEL, Digital Data Logger, Wireless Data Logger |
Brand | Ambetronics |
Model | UIP 800 D |
No. of Channels | Multichannel, 8 |
Usage | Industrial,Laboratory,PHARMA,CALIBRATION |
Warranty | 12 Months From Date Of Invoice |
Power Supply | 85 VAC~260 VAC |
Frequency | 50 Hz and 60 Hz |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Simex |
Application | Laboratory, Industrial |
Model | CMC99 |
Case dimensions | 96 x 96 x 100 mm |
Display | 3.5 inch graphic TFT, 16-bit colour, 320 x 240 pixels, with touchscreen |
Internal memory capacity | internal 1,5 GB |
Power | Electronic |
Model Overview:
Power supply | 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC |
Input | 9 universal inputs max.; 48 analogue inputs (0/4-20 mA or 0/1-5V or 0/2-10V) max.; 48 digital inputs max.; 24 thermocouple inputs max.; 12 RTD inputs max.; 12 counter/ flow meter/ rotameter inputs max.; 1 digital input 24V DC (available in standard, integrated with PS3 or PS4 power supply module) |
Power consumption | typical 15 VA; max. 20 VA |
Display | 3.5 inch graphic TFT, 16-bit colour, 320 x 240 pixels, with touchscreen |
Measurement range | depends on input |
Communication interface | standard: RS-485 (Modbus RTU), 1 x USB Host; ETU version: 1 or 2 x USB Host, 1 x Ethernet 10 MB; enhanced ACM version: 2 x RS-485, 1 x RS-485/232, 1 or 2 x USB Host, 1 x Ethernet 10 MB |
Output | 8 analog (4-20 mA) max.; 16 relay (1A/250V) max.; 4 relay 5A/250V max. or 48 SSR outputs, sensor supply: 24 V DC ± 5% (200 mA max. for current inputs) |
Storage temperature | -10°C ÷ 70°C or -20°C ÷ 70°C (depending on version) |
Available data recording speed | from 0,1 s to 24 h with resolution 0,1 s |
Internal memory capacity | internal 1,5 GB |
Operating temperature | 0°C ÷ 50°C (standard), -20°C ÷ 50°C (option) |
Case | panel mounting |
Case material | NORYL - GFN2S E1 |
Case dimensions | 96 x 96 x 100 mm |
Protection class | IP 65 (front), available options: additional frame IP 65 for panel cut-out sealing, transparent door STD-99; version with front USB: IP 40 or IP 54 (when fitted with STD-99 transparent door) |
Panel cut-out dimensions | 90,5 x 90,5 mm |
Software | Free DAQ Manager software for multi channel controller can be downloaded directly from section „Download” |
Installation depth | min. 102 mm |
Additional Information: